Technical specifications

Rated current32A
Rated voltage230V
Built-in depth69mm
Release characteristicC
Voltage typeAC/DC
Frequency0 - 50Hz
Pollution degree2
Rated insulation voltage Ui500V
Width in number of modular spacings2
Degree of protection (IP)IP20
Number of protected poles1
Current limiting class3
Over voltage category3
Additional equipment possibleYes
Connectable conductor cross section multi-wired0 - 10mm²
Number of poles (total)2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Concurrently switching neutral conductorYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Ambient temperature during operating-25 - 55°C
Suitable for flush-mounted installationNo
Connectable conductor cross section solid-core0 - 16mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSS275101R0324 | SN201 M C32

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current

32A

Rated voltage

230V

Built-in depth

69mm

Release characteristic

C

Voltage type

AC/DC

Frequency

0 .. 50Hz

Pollution degree

2

Rated insulation voltage Ui

500V

Width in number of modular spacings

2

Degree of protection (IP)

IP20

Number of protected poles

1

Current limiting class

3

Over voltage category

3

Additional equipment possible

Connectable conductor cross section multi-wired

0 .. 10mm²

Number of poles (total)

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Ambient temperature during operating

-25 .. 55°C

Suitable for flush-mounted installation

Connectable conductor cross section solid-core

0 .. 16mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated impulse withstand voltage Uimp

4kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.