Aleta.hr

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • ABB

Technical specifications

Number of conductors (without earthing)1
Max. continuous voltage AC275V
Signalling at the deviceOptic
Nominal voltage AC230V
Mounting methodDIN rail (top hat rail) 35 mm
Voltage protection level L-N1.2kV
Nominal discharge surge current (8/20)20kA
Construction size1 modular spacing
Nominal voltage DC-V
Max. continuous voltage DC-V
Voltage protection level1.2kV
Category type 2Yes
With remote signalling contactYes
System configuration TN-SYes
System configuration ITNo
Integrated backup fuseYes
Max. conductor cross section solid (solid, stranded)25mm²
Degree of protection (IP)IP20
System configuration DCNo
System configuration TNYes
Max. PV-voltage-V
System configuration TTYes
Max. conductor cross section flexible (fine-strand)16mm²
Voltage protection level N-PE1.2kV
System configuration TN-CNo
System configuration otherNo
Max. overcurrent protection device, series connection (fuse)50A
Short-circuit breaking capacity (Isccr)50kA
Integrated short-circuit protectionNo
Integrated short-circuit protection selective to fuse gG-A
Max. discharge surge current (8/20)40kA
System configuration TN-C-SYes
Max. overcurrent protection device, parallel connection (fuse)50A
Leakage-current freeNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CTB804201R0100 | OVR T2 40-275

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • ABB

Technical specifications

Number of conductors (without earthing)

1

Max. continuous voltage AC

275V

Signalling at the device

Optic

Nominal voltage AC

230V

Mounting method

DIN rail (top hat rail) 35 mm

Voltage protection level L-N

1.2kV

Nominal discharge surge current (8/20)

20kA

Construction size

1 modular spacing

Nominal voltage DC

-V

Max. continuous voltage DC

-V

Voltage protection level

1.2kV

Category type 2

With remote signalling contact

System configuration TN-S

System configuration IT

Integrated backup fuse

Max. conductor cross section solid (solid, stranded)

25mm²

Degree of protection (IP)

IP20

System configuration DC

System configuration TN

Max. PV-voltage

-V

System configuration TT

Max. conductor cross section flexible (fine-strand)

16mm²

Voltage protection level N-PE

1.2kV

System configuration TN-C

System configuration other

Max. overcurrent protection device, series connection (fuse)

50A

Short-circuit breaking capacity (Isccr)

50kA

Integrated short-circuit protection

Integrated short-circuit protection selective to fuse gG

-A

Max. discharge surge current (8/20)

40kA

System configuration TN-C-S

Max. overcurrent protection device, parallel connection (fuse)

50A

Leakage-current free

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.