Technical specifications

Number of poles3
Type of control elementOther
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Rated permanent current Iu400A
Motor drive integratedNo
Number of auxiliary contacts as change-over contact0
Type of electrical connection of main circuitBolt connection
Motor drive optionalNo
Device constructionBuilt-in device fixed built-in technique
Rated operation power at AC-3, 400 V-kW
Degree of protection (IP), front sideIP20
Suitable for floor mountingYes
Suitable for intermediate mountingYes
Suitable for distribution board installationYes
Max. rated operation voltage Ue AC1000V
Rated operating voltage400 - 690V
Rated short-time withstand current lcw-kA
Conditioned rated short-circuit current Iq-kA
Suitable for front mounting 4-holeYes
Version as reversing switchNo
Rated permanent current at AC-21, 400 V400A
Version as emergency stop installationYes
Voltage release optionalYes
Version as maintenance-/service switchYes
InterlockableYes
Switching power at 400 V220kW
Number of switches1
Colour control elementOther
Rated operation power at AC-23, 400 V220kW
Version as safety switchYes
Suitable for front mounting centreNo
Rated permanent current at AC-23, 400 V400A
Version as main switchYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

35003041 | SIDERMAT 3X400A F

Main Product Image

Details

  • Low-voltage industrial components
  • Switch disconnector
  • 1 KOM
  • SOCOMEC

Technical specifications

Number of poles

3

Type of control element

Other

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Rated permanent current Iu

400A

Motor drive integrated

Number of auxiliary contacts as change-over contact

0

Type of electrical connection of main circuit

Bolt connection

Motor drive optional

Device construction

Built-in device fixed built-in technique

Rated operation power at AC-3, 400 V

-kW

Degree of protection (IP), front side

IP20

Suitable for floor mounting

Suitable for intermediate mounting

Suitable for distribution board installation

Max. rated operation voltage Ue AC

1000V

Rated operating voltage

400 .. 690V

Rated short-time withstand current lcw

-kA

Conditioned rated short-circuit current Iq

-kA

Suitable for front mounting 4-hole

Version as reversing switch

Rated permanent current at AC-21, 400 V

400A

Version as emergency stop installation

Voltage release optional

Version as maintenance-/service switch

Interlockable

Switching power at 400 V

220kW

Number of switches

1

Colour control element

Other

Rated operation power at AC-23, 400 V

220kW

Version as safety switch

Suitable for front mounting centre

Rated permanent current at AC-23, 400 V

400A

Version as main switch