Number of conductors (without earthing)1
Voltage protection level1.4kV
Max. continuous voltage AC280V
Construction size1 modular spacing
With remote signalling contactNo
Nominal discharge surge current (8/20)20kA
Mounting methodDIN rail (top hat rail) 35 mm
Nominal voltage AC280V
Integrated backup fuseNo
Nominal voltage DC0V
Voltage protection level L-N0kV
Degree of protection (IP)IP20
Signalling at the deviceOptic
Max. continuous voltage DC0V
Voltage protection level N-PE0kV
Max. PV-voltage0V
Category type 2Yes
System configuration TNYes
Max. conductor cross section solid (solid, stranded)25mm²
Max. discharge surge current (8/20)40kA
System configuration ITNo
System configuration DCNo
System configuration TN-CNo
System configuration TN-SYes
Max. conductor cross section flexible (fine-strand)35mm²
System configuration TTNo
System configuration TN-C-SNo
System configuration otherYes
Max. overcurrent protection device, parallel connection (fuse)0A
Integrated short-circuit protectionNo
Max. overcurrent protection device, series connection (fuse)125A
Short-circuit breaking capacity (Isccr)0kA
Integrated short-circuit protection selective to fuse gG0A
Leakage-current freeNo

Recommended products


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

SPCT2-280/1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • EATON

Technical specifications

Number of conductors (without earthing)

1

Voltage protection level

1.4kV

Max. continuous voltage AC

280V

Construction size

1 modular spacing

With remote signalling contact

Nominal discharge surge current (8/20)

20kA

Mounting method

DIN rail (top hat rail) 35 mm

Nominal voltage AC

280V

Integrated backup fuse

Nominal voltage DC

0V

Voltage protection level L-N

0kV

Degree of protection (IP)

IP20

Signalling at the device

Optic

Max. continuous voltage DC

0V

Voltage protection level N-PE

0kV

Max. PV-voltage

0V

Category type 2

System configuration TN

Max. conductor cross section solid (solid, stranded)

25mm²

Max. discharge surge current (8/20)

40kA

System configuration IT

System configuration DC

System configuration TN-C

System configuration TN-S

Max. conductor cross section flexible (fine-strand)

35mm²

System configuration TT

System configuration TN-C-S

System configuration other

Max. overcurrent protection device, parallel connection (fuse)

0A

Integrated short-circuit protection

Max. overcurrent protection device, series connection (fuse)

125A

Short-circuit breaking capacity (Isccr)

0kA

Integrated short-circuit protection selective to fuse gG

0A

Leakage-current free