Aleta.hr

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • EATON

Technical specifications

System configuration ITNo
System configuration TN-C-SYes
Nominal discharge surge current (8/20)20kA
System configuration TN-SYes
System configuration DCNo
System configuration otherYes
Nominal voltage DC0V
Max. PV-voltage0V
Max. overcurrent protection device, series connection (fuse)125A
Max. continuous voltage DC0V
Voltage protection level1.4kV
System configuration TNYes
Leakage-current freeNo
Integrated short-circuit protectionNo
Max. overcurrent protection device, parallel connection (fuse)0A
System configuration TTNo
Number of conductors (without earthing)4
Integrated backup fuseNo
Nominal voltage AC280V
Max. continuous voltage AC280V
Voltage protection level N-PE0kV
Integrated short-circuit protection selective to fuse gG0A
Max. conductor cross section solid (solid, stranded)25mm²
Construction size4 modular spacing
Mounting methodDIN rail (top hat rail) 35 mm
Degree of protection (IP)IP20
Signalling at the deviceOptic
Max. discharge surge current (8/20)40kA
Voltage protection level L-N0kV
Short-circuit breaking capacity (Isccr)0kA
Max. conductor cross section flexible (fine-strand)35mm²
System configuration TN-CNo
Category type 2Yes
With remote signalling contactNo

Recommended products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

SPCT2-280/4

Main Product Image

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • EATON

Technical specifications

System configuration IT

System configuration TN-C-S

Nominal discharge surge current (8/20)

20kA

System configuration TN-S

System configuration DC

System configuration other

Nominal voltage DC

0V

Max. PV-voltage

0V

Max. overcurrent protection device, series connection (fuse)

125A

Max. continuous voltage DC

0V

Voltage protection level

1.4kV

System configuration TN

Leakage-current free

Integrated short-circuit protection

Max. overcurrent protection device, parallel connection (fuse)

0A

System configuration TT

Number of conductors (without earthing)

4

Integrated backup fuse

Nominal voltage AC

280V

Max. continuous voltage AC

280V

Voltage protection level N-PE

0kV

Integrated short-circuit protection selective to fuse gG

0A

Max. conductor cross section solid (solid, stranded)

25mm²

Construction size

4 modular spacing

Mounting method

DIN rail (top hat rail) 35 mm

Degree of protection (IP)

IP20

Signalling at the device

Optic

Max. discharge surge current (8/20)

40kA

Voltage protection level L-N

0kV

Short-circuit breaking capacity (Isccr)

0kA

Max. conductor cross section flexible (fine-strand)

35mm²

System configuration TN-C

Category type 2

With remote signalling contact

Recommended products