Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Voltage typeAC
Built-in depth70mm
Rated current16A
Release characteristicB
Surge current capacity0.25kA
Rated voltage400V
Leakage current typeA
Rated insulation voltage Ui500V
Current limiting class3
Rated fault current0.1A
Width in number of modular spacings4
Over voltage category3
Frequency50 Hz
Degree of protection (IP)IP20
Pollution degree2
Concurrently switching neutral conductorYes
Number of protected poles4
Rated short-circuit breaking capacity according to IEC 60947-20kA
Connectable conductor cross section multi-wired1 - 25mm²
Connectable conductor cross section solid-core1 - 25mm²
Suitable for flush-mounted installationNo
Ambient temperature during operating-25 - 40°C
Anti-nuisance tripping versionNo
Rated short-circuit breaking capacity according to EN 610096kA
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Rated impulse withstand voltage Uimp4kV
With interlocking deviceNo
Number of poles (total)4
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

mRB6-16/3N/B/01-A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Voltage type

AC

Built-in depth

70mm

Rated current

16A

Release characteristic

B

Surge current capacity

0.25kA

Rated voltage

400V

Leakage current type

A

Rated insulation voltage Ui

500V

Current limiting class

3

Rated fault current

0.1A

Width in number of modular spacings

4

Over voltage category

3

Frequency

50 Hz

Degree of protection (IP)

IP20

Pollution degree

2

Concurrently switching neutral conductor

Number of protected poles

4

Rated short-circuit breaking capacity according to IEC 60947-2

0kA

Connectable conductor cross section multi-wired

1 .. 25mm²

Connectable conductor cross section solid-core

1 .. 25mm²

Suitable for flush-mounted installation

Ambient temperature during operating

-25 .. 40°C

Anti-nuisance tripping version

Rated short-circuit breaking capacity according to EN 61009

6kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Rated impulse withstand voltage Uimp

4kV

With interlocking device

Number of poles (total)

4

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.