Technical specifications

Built-in depth69.5mm
Over voltage category3
Release characteristicB
Current limiting class3
Rated voltage230V
Frequency50 - 60Hz
Rated current1.5A
Rated insulation voltage Ui440V
Voltage typeAC
Pollution degree2
Degree of protection (IP)IP20
Width in number of modular spacings3
Suitable for flush-mounted installationNo
Ambient temperature during operating-25 - 75°C
Connectable conductor cross section solid-core1 - 25mm²
Additional equipment possibleYes
Number of protected poles3
Concurrently switching neutral conductorNo
Number of poles (total)3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Connectable conductor cross section multi-wired1 - 25mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V0kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V0kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

Item is no longer available for sale!

PL7-B1,5/3

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth

69.5mm

Over voltage category

3

Release characteristic

B

Current limiting class

3

Rated voltage

230V

Frequency

50 .. 60Hz

Rated current

1.5A

Rated insulation voltage Ui

440V

Voltage type

AC

Pollution degree

2

Degree of protection (IP)

IP20

Width in number of modular spacings

3

Suitable for flush-mounted installation

Ambient temperature during operating

-25 .. 75°C

Connectable conductor cross section solid-core

1 .. 25mm²

Additional equipment possible

Number of protected poles

3

Concurrently switching neutral conductor

Number of poles (total)

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Connectable conductor cross section multi-wired

1 .. 25mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

0kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

0kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA