Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Rated voltage230V
Voltage typeAC
Rated current3A
Number of protected poles1
Current limiting class3
Pollution degree2
Built-in depth69.5mm
Width in number of modular spacings1
Concurrently switching neutral conductorNo
Release characteristicB
Frequency50 - 60Hz
Over voltage category3
Degree of protection (IP)IP20
Rated insulation voltage Ui440V
Connectable conductor cross section multi-wired1 - 25mm²
Number of poles (total)1
Connectable conductor cross section solid-core1 - 25mm²
Additional equipment possibleYes
Suitable for flush-mounted installationNo
Ambient temperature during operating-25 - 75°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V0kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V0kA
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

PL7-B3/1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Rated voltage

230V

Voltage type

AC

Rated current

3A

Number of protected poles

1

Current limiting class

3

Pollution degree

2

Built-in depth

69.5mm

Width in number of modular spacings

1

Concurrently switching neutral conductor

Release characteristic

B

Frequency

50 .. 60Hz

Over voltage category

3

Degree of protection (IP)

IP20

Rated insulation voltage Ui

440V

Connectable conductor cross section multi-wired

1 .. 25mm²

Number of poles (total)

1

Connectable conductor cross section solid-core

1 .. 25mm²

Additional equipment possible

Suitable for flush-mounted installation

Ambient temperature during operating

-25 .. 75°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

0kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

0kA

Rated impulse withstand voltage Uimp

4kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.