Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- EATON
Technical specifications
Max. continuous voltage DC
0V
Short-circuit breaking capacity (Isccr)
0kA
Voltage protection level L-N
0kV
Max. overcurrent protection device, parallel connection (fuse)
0A
Max. PV-voltage
0V
Nominal voltage DC
0V
Voltage protection level N-PE
0kV
Integrated short-circuit protection selective to fuse gG
0A
System configuration IT
No
System configuration TT
No
System configuration DC
No
System configuration TN-C
No
System configuration TN-C-S
No
Number of conductors (without earthing)
2
Nominal discharge surge current (8/20)
20kA
System configuration other
Yes
System configuration TN
Yes
Voltage protection level
1.8kV
Integrated short-circuit protection
No
Nominal voltage AC
385V
Max. conductor cross section solid (solid, stranded)
25mm²
Leakage-current free
No
System configuration TN-S
Yes
Integrated backup fuse
No
Max. overcurrent protection device, series connection (fuse)
125A
Mounting method
DIN rail (top hat rail) 35 mm
Max. continuous voltage AC
385V
Max. discharge surge current (8/20)
40kA
Max. conductor cross section flexible (fine-strand)
35mm²
Construction size
2 modular spacing
With remote signalling contact
No
Signalling at the device
Optic
Degree of protection (IP)
IP20
Category type 2
Yes
Recommended products
Substitute products
SPCT2-385/2

Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- EATON
Technical specifications
Max. continuous voltage DC
0V
Short-circuit breaking capacity (Isccr)
0kA
Voltage protection level L-N
0kV
Max. overcurrent protection device, parallel connection (fuse)
0A
Max. PV-voltage
0V
Nominal voltage DC
0V
Voltage protection level N-PE
0kV
Integrated short-circuit protection selective to fuse gG
0A
System configuration IT
System configuration TT
System configuration DC
System configuration TN-C
System configuration TN-C-S
Number of conductors (without earthing)
2
Nominal discharge surge current (8/20)
20kA
System configuration other
System configuration TN
Voltage protection level
1.8kV
Integrated short-circuit protection
Nominal voltage AC
385V
Max. conductor cross section solid (solid, stranded)
25mm²
Leakage-current free
System configuration TN-S
Integrated backup fuse
Max. overcurrent protection device, series connection (fuse)
125A
Mounting method
DIN rail (top hat rail) 35 mm
Max. continuous voltage AC
385V
Max. discharge surge current (8/20)
40kA
Max. conductor cross section flexible (fine-strand)
35mm²
Construction size
2 modular spacing
With remote signalling contact
Signalling at the device
Optic
Degree of protection (IP)
IP20
Category type 2