Aleta.hr

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • EATON

Technical specifications

Mounting methodOn basic element
Construction size1 modular spacing
Nominal voltage AC260V
Nominal discharge surge current (8/20)30kA
Number of conductors (without earthing)0
With remote signalling contactNo
Nominal voltage DC0V
Voltage protection level1kV
Max. continuous voltage AC260V
Category type 2Yes
Max. continuous voltage DC0V
Voltage protection level L-N0kV
Signalling at the deviceOptic
Integrated backup fuseNo
Max. conductor cross section flexible (fine-strand)0mm²
Voltage protection level N-PE0kV
Max. conductor cross section solid (solid, stranded)0mm²
Degree of protection (IP)IP20
Max. PV-voltage0V
System configuration TN-CNo
System configuration TNYes
System configuration DCNo
System configuration ITNo
System configuration otherYes
System configuration TN-C-SNo
System configuration TN-SNo
System configuration TTNo
Short-circuit breaking capacity (Isccr)0kA
Max. discharge surge current (8/20)60kA
Max. overcurrent protection device, series connection (fuse)125A
Max. overcurrent protection device, parallel connection (fuse)0A
Integrated short-circuit protectionNo
Integrated short-circuit protection selective to fuse gG0A
Leakage-current freeNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

SPCT2-NPE60

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • EATON

Technical specifications

Mounting method

On basic element

Construction size

1 modular spacing

Nominal voltage AC

260V

Nominal discharge surge current (8/20)

30kA

Number of conductors (without earthing)

0

With remote signalling contact

Nominal voltage DC

0V

Voltage protection level

1kV

Max. continuous voltage AC

260V

Category type 2

Max. continuous voltage DC

0V

Voltage protection level L-N

0kV

Signalling at the device

Optic

Integrated backup fuse

Max. conductor cross section flexible (fine-strand)

0mm²

Voltage protection level N-PE

0kV

Max. conductor cross section solid (solid, stranded)

0mm²

Degree of protection (IP)

IP20

Max. PV-voltage

0V

System configuration TN-C

System configuration TN

System configuration DC

System configuration IT

System configuration other

System configuration TN-C-S

System configuration TN-S

System configuration TT

Short-circuit breaking capacity (Isccr)

0kA

Max. discharge surge current (8/20)

60kA

Max. overcurrent protection device, series connection (fuse)

125A

Max. overcurrent protection device, parallel connection (fuse)

0A

Integrated short-circuit protection

Integrated short-circuit protection selective to fuse gG

0A

Leakage-current free

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.