Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu350A
Overload release current setting0 - 0A
Number of auxiliary contacts as normally open contact0
Number of poles3
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range undelayed short-circuit release2600 - 3800A
Motor drive optionalNo
Integrated earth fault protectionNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz25kA
Type of control elementRocker lever
Degree of protection (IP)IP20
Number of auxiliary contacts as change-over contact0
Type of electrical connection of main circuitScrew connection
Rated voltage415 - 415V
Motor drive integratedNo
Number of auxiliary contacts as normally closed contact0
Adjustment range short-term delayed short-circuit release0 - 0A
Position of connection for main current circuitFront side
With switched-off indicatorNo
Device constructionBuilt-in device fixed built-in technique
DIN rail (top hat rail) mounting optionalNo
Complete device with protection unitYes
With under voltage releaseNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

BZMB3-A350

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

350A

Overload release current setting

0 .. 0A

Number of auxiliary contacts as normally open contact

0

Number of poles

3

Suitable for DIN rail (top hat rail) mounting

Adjustment range undelayed short-circuit release

2600 .. 3800A

Motor drive optional

Integrated earth fault protection

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

25kA

Type of control element

Rocker lever

Degree of protection (IP)

IP20

Number of auxiliary contacts as change-over contact

0

Type of electrical connection of main circuit

Screw connection

Rated voltage

415 .. 415V

Motor drive integrated

Number of auxiliary contacts as normally closed contact

0

Adjustment range short-term delayed short-circuit release

0 .. 0A

Position of connection for main current circuit

Front side

With switched-off indicator

Device construction

Built-in device fixed built-in technique

DIN rail (top hat rail) mounting optional

Complete device with protection unit

With under voltage release

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.