Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
Overload release current setting0 - 0A
Position of connection for main current circuitFront side
With switched-off indicatorNo
Number of auxiliary contacts as normally closed contact0
Motor drive integratedNo
Number of poles3
Number of auxiliary contacts as normally open contact0
Rated voltage415 - 415V
Rated permanent current Iu250A
Degree of protection (IP)IP20
Type of electrical connection of main circuitScrew connection
Type of control elementRocker lever
Adjustment range short-term delayed short-circuit release0 - 0A
Number of auxiliary contacts as change-over contact0
Device constructionBuilt-in device fixed built-in technique
DIN rail (top hat rail) mounting optionalNo
Adjustment range undelayed short-circuit release2600 - 3800A
Integrated earth fault protectionNo
Complete device with protection unitYes
Suitable for DIN rail (top hat rail) mountingNo
Motor drive optionalNo
With under voltage releaseNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

BZMC3-A250

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

Overload release current setting

0 .. 0A

Position of connection for main current circuit

Front side

With switched-off indicator

Number of auxiliary contacts as normally closed contact

0

Motor drive integrated

Number of poles

3

Number of auxiliary contacts as normally open contact

0

Rated voltage

415 .. 415V

Rated permanent current Iu

250A

Degree of protection (IP)

IP20

Type of electrical connection of main circuit

Screw connection

Type of control element

Rocker lever

Adjustment range short-term delayed short-circuit release

0 .. 0A

Number of auxiliary contacts as change-over contact

0

Device construction

Built-in device fixed built-in technique

DIN rail (top hat rail) mounting optional

Adjustment range undelayed short-circuit release

2600 .. 3800A

Integrated earth fault protection

Complete device with protection unit

Suitable for DIN rail (top hat rail) mounting

Motor drive optional

With under voltage release

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.