Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

With switched-off indicatorNo
Number of auxiliary contacts as change-over contact0
Rated permanent current Iu320A
Number of auxiliary contacts as normally open contact0
Rated voltage415 - 415V
Number of poles3
Type of electrical connection of main circuitScrew connection
Number of auxiliary contacts as normally closed contact0
Overload release current setting0 - 0A
Degree of protection (IP)IP20
Type of control elementRocker lever
Position of connection for main current circuitFront side
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
Adjustment range short-term delayed short-circuit release0 - 0A
Motor drive integratedNo
Adjustment range undelayed short-circuit release2600 - 3800A
Motor drive optionalNo
Device constructionBuilt-in device fixed built-in technique
Integrated earth fault protectionNo
Suitable for DIN rail (top hat rail) mountingNo
Complete device with protection unitYes
With under voltage releaseNo
DIN rail (top hat rail) mounting optionalNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

BZMC3-A320

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

With switched-off indicator

Number of auxiliary contacts as change-over contact

0

Rated permanent current Iu

320A

Number of auxiliary contacts as normally open contact

0

Rated voltage

415 .. 415V

Number of poles

3

Type of electrical connection of main circuit

Screw connection

Number of auxiliary contacts as normally closed contact

0

Overload release current setting

0 .. 0A

Degree of protection (IP)

IP20

Type of control element

Rocker lever

Position of connection for main current circuit

Front side

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

Adjustment range short-term delayed short-circuit release

0 .. 0A

Motor drive integrated

Adjustment range undelayed short-circuit release

2600 .. 3800A

Motor drive optional

Device construction

Built-in device fixed built-in technique

Integrated earth fault protection

Suitable for DIN rail (top hat rail) mounting

Complete device with protection unit

With under voltage release

DIN rail (top hat rail) mounting optional