  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Number of auxiliary contacts as normally open contact0
Rated permanent current Iu400A
With under voltage releaseNo
Device constructionBuilt-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mountingNo
DIN rail (top hat rail) mounting optionalNo
Position of connection for main current circuitFront side
Number of auxiliary contacts as normally closed contact0
Type of control elementRocker lever
Number of auxiliary contacts as change-over contact0
Rated voltage415 - 415V
Type of electrical connection of main circuitScrew connection
With switched-off indicatorNo
Degree of protection (IP)IP20
Adjustment range short-term delayed short-circuit release0 - 0A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
Adjustment range undelayed short-circuit release2600 - 3800A
Complete device with protection unitYes
Motor drive integratedNo
Integrated earth fault protectionNo
Motor drive optionalNo
Number of poles3
Overload release current setting0 - 0A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

BZMC3-A400

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Number of auxiliary contacts as normally open contact

0

Rated permanent current Iu

400A

With under voltage release

Device construction

Built-in device fixed built-in technique

Suitable for DIN rail (top hat rail) mounting

DIN rail (top hat rail) mounting optional

Position of connection for main current circuit

Front side

Number of auxiliary contacts as normally closed contact

0

Type of control element

Rocker lever

Number of auxiliary contacts as change-over contact

0

Rated voltage

415 .. 415V

Type of electrical connection of main circuit

Screw connection

With switched-off indicator

Degree of protection (IP)

IP20

Adjustment range short-term delayed short-circuit release

0 .. 0A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

Adjustment range undelayed short-circuit release

2600 .. 3800A

Complete device with protection unit

Motor drive integrated

Integrated earth fault protection

Motor drive optional

Number of poles

3

Overload release current setting

0 .. 0A