Technical specifications

Type of switch functionOther
Number of protected contact energized outputs0
Number of protected semiconductor outputs0
Type of electric connectionOther
Number of contact energized outputs with signalling function0
With time functionNo
Rated control supply voltage Us at AC 60HZ0 - 0V
Material housingPlastic
Max. output current100mA
Type of interface for safety communicationOther
Rated control supply voltage Us at AC 50HZ0 - 0V
Type of switching outputPNP/NPN
Ambient temperature-35 - 55°C
Number of semiconductor outputs with signalling function2
Voltage typeDC
Suitable for safety functionsNo
Switching frequency0Hz
Rated control supply voltage Us at DC18 - 30V
Adjustment range0 - 900mm
Operation agent-safety classSafety class 2
Type of lightInfrared light
Pre failure noticeNo
Laser protection classNone
Degree of protection (IP)IP67
Material of optical surfacePlastic
Switching voltage of OSSD at state "high"30V
Analogue output 0 mA ... 20 mANo
Min. reflector distance0mm
Analogue output 4 mA ... 20 mANo
Material of cable sheathOther
Analogue output -10 V ... +10 VNo
Analogue output 0 V ... 10 VNo
Light dot0mm²
With monitoring function downstream switching devicesNo
Wavelength of the sensor0nm
With restart blockageNo
Max. output current at protected output0mA
Transmission range of the safety field0m
Construction type housingCuboid
Setting procedureOther
Explosion safety category for dustNone
Explosion safety category for gasNone
Response time15ms
With communication interface analogueNo
With communication interface EthernetNo
With communication interface DeviceNetNo
Height of sensor59mm
With communication interface RS-232No
With communication interface CANOpenNo
With communication interface INTERBUSNo
With communication interface RS-422No
With communication interface AS-InterfaceNo
With communication interface PROFIBUSNo
Width sensor43mm
AWG-number0
With communication interface SSDNo
With communication interface RS-485No
Rated switching distance900mm
With other analogue outputNo
Length of sensor166mm
With communication interface SSINo
Max. switching distance1200mm
Diameter sensor0mm
With reflectorNo
Sensing modeLight switching
TriangulationBackground fade-out
Operating distance0 - 0mm
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

E67-LRDP090-HLD

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Sensors
  • Light scanner with background masking
  • 1 KOM
  • EATON

Technical specifications

Type of switch function

Other

Number of protected contact energized outputs

0

Number of protected semiconductor outputs

0

Type of electric connection

Other

Number of contact energized outputs with signalling function

0

With time function

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Material housing

Plastic

Max. output current

100mA

Type of interface for safety communication

Other

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Type of switching output

PNP/NPN

Ambient temperature

-35 .. 55°C

Number of semiconductor outputs with signalling function

2

Voltage type

DC

Suitable for safety functions

Switching frequency

0Hz

Rated control supply voltage Us at DC

18 .. 30V

Adjustment range

0 .. 900mm

Operation agent-safety class

Safety class 2

Type of light

Infrared light

Pre failure notice

Laser protection class

None

Degree of protection (IP)

IP67

Material of optical surface

Plastic

Switching voltage of OSSD at state "high"

30V

Analogue output 0 mA ... 20 mA

Min. reflector distance

0mm

Analogue output 4 mA ... 20 mA

Material of cable sheath

Other

Analogue output -10 V ... +10 V

Analogue output 0 V ... 10 V

Light dot

0mm²

With monitoring function downstream switching devices

Wavelength of the sensor

0nm

With restart blockage

Max. output current at protected output

0mA

Transmission range of the safety field

0m

Construction type housing

Cuboid

Setting procedure

Other

Explosion safety category for dust

None

Explosion safety category for gas

None

Response time

15ms

With communication interface analogue

With communication interface Ethernet

With communication interface DeviceNet

Height of sensor

59mm

With communication interface RS-232

With communication interface CANOpen

With communication interface INTERBUS

With communication interface RS-422

With communication interface AS-Interface

With communication interface PROFIBUS

Width sensor

43mm

AWG-number

0

With communication interface SSD

With communication interface RS-485

Rated switching distance

900mm

With other analogue output

Length of sensor

166mm

With communication interface SSI

Max. switching distance

1200mm

Diameter sensor

0mm

With reflector

Sensing mode

Light switching

Triangulation

Background fade-out

Operating distance

0 .. 0mm