Aleta.hr

Details

  • Sensors
  • Light scanner with background masking
  • 1 KOM
  • EATON

Technical specifications

Voltage typeDC
Suitable for safety functionsNo
Rated control supply voltage Us at AC 60HZ0 - 0V
Rated control supply voltage Us at AC 50HZ0 - 0V
Rated control supply voltage Us at DC18 - 30V
Number of protected semiconductor outputs0
Number of semiconductor outputs with signalling function2
Material housingPlastic
Type of switch functionOther
With time functionNo
Number of contact energized outputs with signalling function0
Type of switching outputPNP/NPN
Max. output current100mA
Adjustment range0 - 2400mm
Number of protected contact energized outputs0
Type of electric connectionOther
Type of interface for safety communicationOther
Ambient temperature-35 - 55°C
Switching frequency0Hz
Operation agent-safety classSafety class 2
Setting procedureOther
Analogue output -10 V ... +10 VNo
Pre failure noticeNo
Response time15ms
Switching voltage of OSSD at state "high"30V
Wavelength of the sensor0nm
Degree of protection (IP)IP67
Type of lightInfrared light
With restart blockageNo
Material of cable sheathOther
Analogue output 0 V ... 10 VNo
Analogue output 0 mA ... 20 mANo
Laser protection classNone
Explosion safety category for dustNone
Transmission range of the safety field0m
Min. reflector distance0mm
Explosion safety category for gasNone
Material of optical surfacePlastic
Construction type housingCuboid
Max. output current at protected output0mA
Analogue output 4 mA ... 20 mANo
With monitoring function downstream switching devicesNo
AWG-number0
Light dot0mm²
Sensing modeLight switching
With communication interface PROFIBUSNo
With communication interface AS-InterfaceNo
With communication interface DeviceNetNo
Rated switching distance2400mm
With communication interface RS-232No
With communication interface INTERBUSNo
With communication interface RS-422No
With communication interface SSINo
With communication interface CANOpenNo
With communication interface analogueNo
With other analogue outputNo
With communication interface SSDNo
Length of sensor166mm
Height of sensor59mm
Operating distance0 - 0mm
With reflectorNo
With communication interface RS-485No
Diameter sensor0mm
Width sensor43mm
TriangulationBackground fade-out
Max. switching distance2700mm
With communication interface EthernetNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

E67-LRDP240-HLD

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Sensors
  • Light scanner with background masking
  • 1 KOM
  • EATON

Technical specifications

Voltage type

DC

Suitable for safety functions

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Rated control supply voltage Us at DC

18 .. 30V

Number of protected semiconductor outputs

0

Number of semiconductor outputs with signalling function

2

Material housing

Plastic

Type of switch function

Other

With time function

Number of contact energized outputs with signalling function

0

Type of switching output

PNP/NPN

Max. output current

100mA

Adjustment range

0 .. 2400mm

Number of protected contact energized outputs

0

Type of electric connection

Other

Type of interface for safety communication

Other

Ambient temperature

-35 .. 55°C

Switching frequency

0Hz

Operation agent-safety class

Safety class 2

Setting procedure

Other

Analogue output -10 V ... +10 V

Pre failure notice

Response time

15ms

Switching voltage of OSSD at state "high"

30V

Wavelength of the sensor

0nm

Degree of protection (IP)

IP67

Type of light

Infrared light

With restart blockage

Material of cable sheath

Other

Analogue output 0 V ... 10 V

Analogue output 0 mA ... 20 mA

Laser protection class

None

Explosion safety category for dust

None

Transmission range of the safety field

0m

Min. reflector distance

0mm

Explosion safety category for gas

None

Material of optical surface

Plastic

Construction type housing

Cuboid

Max. output current at protected output

0mA

Analogue output 4 mA ... 20 mA

With monitoring function downstream switching devices

AWG-number

0

Light dot

0mm²

Sensing mode

Light switching

With communication interface PROFIBUS

With communication interface AS-Interface

With communication interface DeviceNet

Rated switching distance

2400mm

With communication interface RS-232

With communication interface INTERBUS

With communication interface RS-422

With communication interface SSI

With communication interface CANOpen

With communication interface analogue

With other analogue output

With communication interface SSD

Length of sensor

166mm

Height of sensor

59mm

Operating distance

0 .. 0mm

With reflector

With communication interface RS-485

Diameter sensor

0mm

Width sensor

43mm

Triangulation

Background fade-out

Max. switching distance

2700mm

With communication interface Ethernet

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.