Technical specifications
Height
272mm
Width
45mm
Rated operation current Ie
16.7A
Depth
145mm
Number of auxiliary contacts as normally open contact
0
Rated operation power at AC-3, 400 V
7.5kW
With transformer
Number of auxiliary contacts as normally closed contact
1
Number of indicator lights
0
Number of command positions
0
Suitable for emergency stop
Supporting protocol for TCP/IP
Supporting protocol for CAN
Supporting protocol for INTERBUS
Supporting protocol for Modbus
Supporting protocol for PROFIBUS
Supporting protocol for LON
Supporting protocol for ASI
Overload release current setting
0.3 .. 1.2A
Supporting protocol for DeviceNet
Supporting protocol for other bus systems
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Supporting protocol for SUCONET
Rail mounting possible
External reset possible
Supporting protocol for Data-Highway
Rated control supply voltage Us at AC 50HZ
0 .. 0V
Degree of protection (IP)
IP20
Rated control supply voltage Us at DC
24 .. 24V
With short-circuit release
Release class
Adjustable
Type of electrical connection of main circuit
Screw connection
Supporting protocol for INTERBUS-Safety
Supporting protocol for PROFINET IO
Supporting protocol for EtherNet/IP
Supporting protocol for SERCOS
Supporting protocol for PROFIsafe
Supporting protocol for Foundation Fieldbus
With fuse
Supporting protocol for DeviceNet Safety
Supporting protocol for PROFINET CBA
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Supporting protocol for AS-Interface Safety at Work
Voltage type for actuating
DC
Rated operation current at AC-3, 400 V
1.2A
Ambient temperature, upper operating limit
55°C
Rated power, 575 V, 60 Hz, 3-phase
0.37kW
Type of motor starter
Direct online starter (DOL)
Rated operation power at AC-3, 230 V, 3-phase
0.18kW
Rated power, 460 V, 60 Hz, 3-phase
0.37kW
Supporting protocol for SafetyBUS p
Temperature compensated overload protection
Rated conditional short-circuit current, type 2, 400 V
0A
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Coordination class according to IEC 60947-4-3
Class 2
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Degree of protection (NEMA)
Other
Rated conditional short-circuit current, type 2, 230 V
0A