Details
- •Low-voltage industrial components
- •Motor starter/motor starter combination
- •1 KOM
- •EATON
Technical specifications
Depth145mm
Width45mm
Height272mm
Number of auxiliary contacts as normally open contact0
Number of command positions0
With transformerNo
Number of auxiliary contacts as normally closed contact1
Suitable for emergency stopNo
Number of indicator lights0
Supporting protocol for PROFIBUSNo
Supporting protocol for TCP/IPNo
Supporting protocol for ASINo
Supporting protocol for LONNo
Supporting protocol for Data-HighwayNo
Supporting protocol for ModbusNo
Supporting protocol for CANNo
Supporting protocol for INTERBUSNo
Supporting protocol for DeviceNetNo
Supporting protocol for SUCONETNo
Rated control supply voltage Us at AC 60HZ0 - 0V
Rated control supply voltage Us at AC 50HZ0 - 0V
Supporting protocol for other bus systemsYes
External reset possibleNo
Rail mounting possibleNo
Release classAdjustable
Type of electrical connection of main circuitScrew connection
With fuseNo
Supporting protocol for SERCOSNo
Type of electrical connection for auxiliary- and control current circuitScrew connection
Supporting protocol for DeviceNet SafetyNo
With short-circuit releaseYes
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for SafetyBUS pNo
Rated operation power at AC-3, 230 V, 3-phase3kW
Supporting protocol for EtherNet/IPNo
Voltage type for actuatingDC
Supporting protocol for PROFIsafeNo
Supporting protocol for PROFINET IONo
Supporting protocol for PROFINET CBANo
Rated power, 460 V, 60 Hz, 3-phase5.52kW
Rated power, 575 V, 60 Hz, 3-phase0kW
Rated conditional short-circuit current, type 2, 400 V0A
Ambient temperature, upper operating limit55°C
Temperature compensated overload protectionYes
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Degree of protection (NEMA)Other
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Rated conditional short-circuit current, type 2, 230 V0A
Coordination class according to IEC 60947-4-3Class 2
Rated operation power at AC-3, 400 V7.5kW
Rated operation current Ie16.7A
Overload release current setting3 - 12A
Degree of protection (IP)IP20
Rated control supply voltage Us at DC24 - 24V
Type of motor starterDirect online starter (DOL)
Rated operation current at AC-3, 400 V12A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user