Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

With transformerNo
Number of command positions0
Rated operation power at AC-3, 400 V7.5kW
Width45mm
Number of auxiliary contacts as normally closed contact1
Depth145mm
Height272mm
Number of auxiliary contacts as normally open contact0
Supporting protocol for ModbusNo
Supporting protocol for ASINo
Number of indicator lights0
Suitable for emergency stopNo
Supporting protocol for INTERBUSNo
Supporting protocol for CANNo
Supporting protocol for LONNo
Rated operation current Ie16.7A
Supporting protocol for PROFIBUSNo
Overload release current setting1 - 4A
Supporting protocol for TCP/IPNo
Supporting protocol for Data-HighwayNo
Supporting protocol for SUCONETNo
Supporting protocol for DeviceNetNo
Supporting protocol for other bus systemsYes
External reset possibleNo
Supporting protocol for SERCOSNo
Degree of protection (IP)IP20
Rated control supply voltage Us at AC 60HZ0 - 0V
Rated control supply voltage Us at AC 50HZ0 - 0V
Rated control supply voltage Us at DC24 - 24V
Rail mounting possibleNo
Supporting protocol for INTERBUS-SafetyNo
Type of electrical connection of main circuitScrew connection
With short-circuit releaseYes
With fuseNo
Release classAdjustable
Type of electrical connection for auxiliary- and control current circuitScrew connection
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFIsafeNo
Supporting protocol for PROFINET IONo
Type of motor starterDirect online starter (DOL)
Rated power, 575 V, 60 Hz, 3-phase0kW
Rated power, 460 V, 60 Hz, 3-phase1.47kW
Coordination class according to IEC 60947-4-3Class 2
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Rated conditional short-circuit current, type 2, 230 V0A
Degree of protection (NEMA)Other
Rated operation current at AC-3, 400 V4A
Voltage type for actuatingDC
Ambient temperature, upper operating limit55°C
Rated operation power at AC-3, 230 V, 3-phase0.75kW
Temperature compensated overload protectionYes
Rated conditional short-circuit current, type 2, 400 V0A
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-DEA-4-M17-SP(24VDC)

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

With transformer

Number of command positions

0

Rated operation power at AC-3, 400 V

7.5kW

Width

45mm

Number of auxiliary contacts as normally closed contact

1

Depth

145mm

Height

272mm

Number of auxiliary contacts as normally open contact

0

Supporting protocol for Modbus

Supporting protocol for ASI

Number of indicator lights

0

Suitable for emergency stop

Supporting protocol for INTERBUS

Supporting protocol for CAN

Supporting protocol for LON

Rated operation current Ie

16.7A

Supporting protocol for PROFIBUS

Overload release current setting

1 .. 4A

Supporting protocol for TCP/IP

Supporting protocol for Data-Highway

Supporting protocol for SUCONET

Supporting protocol for DeviceNet

Supporting protocol for other bus systems

External reset possible

Supporting protocol for SERCOS

Degree of protection (IP)

IP20

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Rated control supply voltage Us at DC

24 .. 24V

Rail mounting possible

Supporting protocol for INTERBUS-Safety

Type of electrical connection of main circuit

Screw connection

With short-circuit release

With fuse

Release class

Adjustable

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for EtherNet/IP

Supporting protocol for DeviceNet Safety

Supporting protocol for Foundation Fieldbus

Supporting protocol for SafetyBUS p

Supporting protocol for PROFINET CBA

Supporting protocol for PROFIsafe

Supporting protocol for PROFINET IO

Type of motor starter

Direct online starter (DOL)

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated power, 460 V, 60 Hz, 3-phase

1.47kW

Coordination class according to IEC 60947-4-3

Class 2

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated conditional short-circuit current, type 2, 230 V

0A

Degree of protection (NEMA)

Other

Rated operation current at AC-3, 400 V

4A

Voltage type for actuating

DC

Ambient temperature, upper operating limit

55°C

Rated operation power at AC-3, 230 V, 3-phase

0.75kW

Temperature compensated overload protection

Rated conditional short-circuit current, type 2, 400 V

0A

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.