Technical specifications

Overload release current setting1600.0 - 4000A
Rated permanent current Iu4000A
With switched-off indicatorYes
Position of connection for main current circuitBack side
Number of auxiliary contacts as normally closed contact0
Motor drive integratedNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz80kA
Type of control elementPush button
Type of electrical connection of main circuitBolt connection
Number of poles4
Number of auxiliary contacts as change-over contact4
Number of auxiliary contacts as normally open contact0
Rated voltage690 - 690V
Degree of protection (IP)IP30
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range undelayed short-circuit release6000.0 - 60000A
Adjustment range short-term delayed short-circuit release4000 - 40000A
Motor drive optionalYes
Device constructionBuilt-in device fixed built-in technique
Integrated earth fault protectionYes
DIN rail (top hat rail) mounting optionalNo
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA055538R1 | E4S/F 4000 PR121/P-LSIG IN=4000A 4P

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Overload release current setting

1600.0 .. 4000A

Rated permanent current Iu

4000A

With switched-off indicator

Position of connection for main current circuit

Back side

Number of auxiliary contacts as normally closed contact

0

Motor drive integrated

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

80kA

Type of control element

Push button

Type of electrical connection of main circuit

Bolt connection

Number of poles

4

Number of auxiliary contacts as change-over contact

4

Number of auxiliary contacts as normally open contact

0

Rated voltage

690 .. 690V

Degree of protection (IP)

IP30

Suitable for DIN rail (top hat rail) mounting

Adjustment range undelayed short-circuit release

6000.0 .. 60000A

Adjustment range short-term delayed short-circuit release

4000 .. 40000A

Motor drive optional

Device construction

Built-in device fixed built-in technique

Integrated earth fault protection

DIN rail (top hat rail) mounting optional

Complete device with protection unit