Technical specifications
Type of electrical connection of main circuit
Connection at separate chassis part
Integrated earth fault protection
Yes
Rated permanent current Iu
4000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
80kA
Suitable for DIN rail (top hat rail) mounting
No
Adjustment range undelayed short-circuit release
6000.0 - 60000A
Overload release current setting
1600.0 - 4000A
Device construction
Built-in device slide-in technique (withdrawable)
Rated voltage
690 - 690V
Adjustment range short-term delayed short-circuit release
2400.0 - 2400.0A
Number of auxiliary contacts as normally closed contact
0
With switched-off indicator
Yes
DIN rail (top hat rail) mounting optional
No
Number of auxiliary contacts as change-over contact
4
Number of poles
4
Number of auxiliary contacts as normally open contact
0
Position of connection for main current circuit
Connection at separate chassis part
Complete device with protection unit
Yes
Motor drive optional
Yes
Type of control element
Push button
Degree of protection (IP)
IP30
Motor drive integrated
No
From same serie
1SDA055551R1 | E4S/F 4000 PR123/P-LSIG IN=4000A 4P W MP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Type of electrical connection of main circuit
Connection at separate chassis part
Integrated earth fault protection
Rated permanent current Iu
4000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
80kA
Suitable for DIN rail (top hat rail) mounting
Adjustment range undelayed short-circuit release
6000.0 .. 60000A
Overload release current setting
1600.0 .. 4000A
Device construction
Built-in device slide-in technique (withdrawable)
Rated voltage
690 .. 690V
Adjustment range short-term delayed short-circuit release
2400.0 .. 2400.0A
Number of auxiliary contacts as normally closed contact
0
With switched-off indicator
DIN rail (top hat rail) mounting optional
Number of auxiliary contacts as change-over contact
4
Number of poles
4
Number of auxiliary contacts as normally open contact
0
Position of connection for main current circuit
Connection at separate chassis part
Complete device with protection unit
Motor drive optional
Type of control element
Push button
Degree of protection (IP)
IP30
Motor drive integrated
From same serie