Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Adjustment range undelayed short-circuit release7500.0 - 75000A
Rated voltage690 - 690V
Rated permanent current Iu5000A
With switched-off indicatorYes
Position of connection for main current circuitBack side
Overload release current setting2000.0 - 5000A
Motor drive integratedNo
Number of poles4
Number of auxiliary contacts as change-over contact4
Type of electrical connection of main circuitBolt connection
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz100kA
Adjustment range short-term delayed short-circuit release5000 - 50000A
Degree of protection (IP)IP30
Suitable for DIN rail (top hat rail) mountingNo
Type of control elementPush button
Integrated earth fault protectionNo
Motor drive optionalYes
Complete device with protection unitYes
DIN rail (top hat rail) mounting optionalNo
Device constructionBuilt-in device fixed built-in technique
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA055568R1 | E6H/F 5000 PR121/P-LI IN=5000A 4P F HR

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Adjustment range undelayed short-circuit release

7500.0 .. 75000A

Rated voltage

690 .. 690V

Rated permanent current Iu

5000A

With switched-off indicator

Position of connection for main current circuit

Back side

Overload release current setting

2000.0 .. 5000A

Motor drive integrated

Number of poles

4

Number of auxiliary contacts as change-over contact

4

Type of electrical connection of main circuit

Bolt connection

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

100kA

Adjustment range short-term delayed short-circuit release

5000 .. 50000A

Degree of protection (IP)

IP30

Suitable for DIN rail (top hat rail) mounting

Type of control element

Push button

Integrated earth fault protection

Motor drive optional

Complete device with protection unit

DIN rail (top hat rail) mounting optional

Device construction

Built-in device fixed built-in technique