Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Rated voltage
690 - 690V
Adjustment range short-term delayed short-circuit release
5000 - 50000A
Rated permanent current Iu
5000A
Adjustment range undelayed short-circuit release
7500.0 - 75000A
Integrated earth fault protection
No
Overload release current setting
2000.0 - 5000A
Device construction
Built-in device slide-in technique (withdrawable)
DIN rail (top hat rail) mounting optional
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Position of connection for main current circuit
Connection at separate chassis part
Type of electrical connection of main circuit
Connection at separate chassis part
Number of auxiliary contacts as normally open contact
0
With switched-off indicator
Yes
Type of control element
Push button
Complete device with protection unit
Yes
Suitable for DIN rail (top hat rail) mounting
No
Number of auxiliary contacts as change-over contact
4
Number of poles
4
Motor drive integrated
No
Motor drive optional
Yes
Degree of protection (IP)
IP30
From same serie
1SDA055577R1 | E6H/F 5000 PR121/P-LSI IN=5000A 4P W MP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Rated voltage
690 .. 690V
Adjustment range short-term delayed short-circuit release
5000 .. 50000A
Rated permanent current Iu
5000A
Adjustment range undelayed short-circuit release
7500.0 .. 75000A
Integrated earth fault protection
Overload release current setting
2000.0 .. 5000A
Device construction
Built-in device slide-in technique (withdrawable)
DIN rail (top hat rail) mounting optional
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Position of connection for main current circuit
Connection at separate chassis part
Type of electrical connection of main circuit
Connection at separate chassis part
Number of auxiliary contacts as normally open contact
0
With switched-off indicator
Type of control element
Push button
Complete device with protection unit
Suitable for DIN rail (top hat rail) mounting
Number of auxiliary contacts as change-over contact
4
Number of poles
4
Motor drive integrated
Motor drive optional
Degree of protection (IP)
IP30
From same serie