Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Type of electrical connection of main circuitBolt connection
Number of auxiliary contacts as change-over contact4
Rated permanent current Iu1600A
Number of auxiliary contacts as normally open contact0
Motor drive integratedNo
Number of auxiliary contacts as normally closed contact0
Degree of protection (IP)IP30
Position of connection for main current circuitBack side
Number of poles4
Rated voltage690 - 690V
With switched-off indicatorYes
Type of control elementPush button
Overload release current setting640.0 - 1600A
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range short-term delayed short-circuit release1600 - 16000A
Adjustment range undelayed short-circuit release2400.0 - 24000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz42kA
DIN rail (top hat rail) mounting optionalNo
Motor drive optionalYes
Integrated earth fault protectionYes
Device constructionBuilt-in device fixed built-in technique
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA055674R1 | E1B 1600 PR121/P-LSIG IN=1600A 4P F HR

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Type of electrical connection of main circuit

Bolt connection

Number of auxiliary contacts as change-over contact

4

Rated permanent current Iu

1600A

Number of auxiliary contacts as normally open contact

0

Motor drive integrated

Number of auxiliary contacts as normally closed contact

0

Degree of protection (IP)

IP30

Position of connection for main current circuit

Back side

Number of poles

4

Rated voltage

690 .. 690V

With switched-off indicator

Type of control element

Push button

Overload release current setting

640.0 .. 1600A

Suitable for DIN rail (top hat rail) mounting

Adjustment range short-term delayed short-circuit release

1600 .. 16000A

Adjustment range undelayed short-circuit release

2400.0 .. 24000A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

42kA

DIN rail (top hat rail) mounting optional

Motor drive optional

Integrated earth fault protection

Device construction

Built-in device fixed built-in technique

Complete device with protection unit

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.