Technical specifications

Overload release current setting320.0 - 800A
Rated permanent current Iu800A
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Type of electrical connection of main circuitBolt connection
Motor drive integratedNo
Rated voltage690 - 690V
Degree of protection (IP)IP30
Number of auxiliary contacts as change-over contact4
Number of poles3
Position of connection for main current circuitBack side
Complete device with protection unitYes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Motor drive optionalYes
Integrated earth fault protectionNo
Device constructionBuilt-in device fixed built-in technique
Adjustment range undelayed short-circuit release1200.0 - 12000A
Suitable for DIN rail (top hat rail) mountingNo
With switched-off indicatorYes
DIN rail (top hat rail) mounting optionalNo
Adjustment range short-term delayed short-circuit release800 - 8000A
Type of control elementPush button
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA055697R1 | E1N 800 PR121/P-LSI IN=800A 3P F HR

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Overload release current setting

320.0 .. 800A

Rated permanent current Iu

800A

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Type of electrical connection of main circuit

Bolt connection

Motor drive integrated

Rated voltage

690 .. 690V

Degree of protection (IP)

IP30

Number of auxiliary contacts as change-over contact

4

Number of poles

3

Position of connection for main current circuit

Back side

Complete device with protection unit

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Motor drive optional

Integrated earth fault protection

Device construction

Built-in device fixed built-in technique

Adjustment range undelayed short-circuit release

1200.0 .. 12000A

Suitable for DIN rail (top hat rail) mounting

With switched-off indicator

DIN rail (top hat rail) mounting optional

Adjustment range short-term delayed short-circuit release

800 .. 8000A

Type of control element

Push button

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.