Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Adjustment range short-term delayed short-circuit release480.0 - 480.0A
Rated voltage690 - 690V
Rated permanent current Iu800A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Overload release current setting320.0 - 800A
Integrated earth fault protectionNo
Adjustment range undelayed short-circuit release1200.0 - 12000A
Suitable for DIN rail (top hat rail) mountingNo
Type of electrical connection of main circuitBolt connection
Number of auxiliary contacts as normally open contact0
Device constructionBuilt-in device fixed built-in technique
Number of auxiliary contacts as normally closed contact0
With switched-off indicatorYes
Number of auxiliary contacts as change-over contact4
Position of connection for main current circuitBack side
Number of poles3
Complete device with protection unitYes
Type of control elementPush button
Motor drive optionalYes
Degree of protection (IP)IP30
Motor drive integratedNo
DIN rail (top hat rail) mounting optionalNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA055699R1 | E1N 800 PR122/P-LI IN=800A 3P F HR

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Adjustment range short-term delayed short-circuit release

480.0 .. 480.0A

Rated voltage

690 .. 690V

Rated permanent current Iu

800A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Overload release current setting

320.0 .. 800A

Integrated earth fault protection

Adjustment range undelayed short-circuit release

1200.0 .. 12000A

Suitable for DIN rail (top hat rail) mounting

Type of electrical connection of main circuit

Bolt connection

Number of auxiliary contacts as normally open contact

0

Device construction

Built-in device fixed built-in technique

Number of auxiliary contacts as normally closed contact

0

With switched-off indicator

Number of auxiliary contacts as change-over contact

4

Position of connection for main current circuit

Back side

Number of poles

3

Complete device with protection unit

Type of control element

Push button

Motor drive optional

Degree of protection (IP)

IP30

Motor drive integrated

DIN rail (top hat rail) mounting optional

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.