Technical specifications

Degree of protection (IP)IP30
Position of connection for main current circuitBack side
Number of poles4
With switched-off indicatorYes
Number of auxiliary contacts as change-over contact4
Overload release current setting320.0 - 800A
Rated voltage690 - 690V
Motor drive integratedNo
Rated permanent current Iu800A
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Type of control elementPush button
Type of electrical connection of main circuitBolt connection
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Adjustment range short-term delayed short-circuit release480.0 - 480.0A
DIN rail (top hat rail) mounting optionalNo
Suitable for DIN rail (top hat rail) mountingNo
Device constructionBuilt-in device fixed built-in technique
Complete device with protection unitYes
Integrated earth fault protectionNo
Motor drive optionalYes
Adjustment range undelayed short-circuit release1200.0 - 12000A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA055708R1 | E1N 800 PR122/P-LSI IN=800A 4P F HR

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Degree of protection (IP)

IP30

Position of connection for main current circuit

Back side

Number of poles

4

With switched-off indicator

Number of auxiliary contacts as change-over contact

4

Overload release current setting

320.0 .. 800A

Rated voltage

690 .. 690V

Motor drive integrated

Rated permanent current Iu

800A

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Type of control element

Push button

Type of electrical connection of main circuit

Bolt connection

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Adjustment range short-term delayed short-circuit release

480.0 .. 480.0A

DIN rail (top hat rail) mounting optional

Suitable for DIN rail (top hat rail) mounting

Device construction

Built-in device fixed built-in technique

Complete device with protection unit

Integrated earth fault protection

Motor drive optional

Adjustment range undelayed short-circuit release

1200.0 .. 12000A

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.