

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated voltage
690 - 690V
Adjustment range short-term delayed short-circuit release
960.0 - 960.0A
Overload release current setting
640.0 - 1600A
Integrated earth fault protection
No
Rated permanent current Iu
1600A
Adjustment range undelayed short-circuit release
2400.0 - 24000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Device construction
Built-in device slide-in technique (withdrawable)
Type of electrical connection of main circuit
Connection at separate chassis part
DIN rail (top hat rail) mounting optional
No
Suitable for DIN rail (top hat rail) mounting
No
Number of auxiliary contacts as change-over contact
4
Number of auxiliary contacts as normally closed contact
0
With switched-off indicator
Yes
Number of auxiliary contacts as normally open contact
0
Position of connection for main current circuit
Connection at separate chassis part
Number of poles
4
Complete device with protection unit
Yes
Motor drive integrated
No
Motor drive optional
Yes
Degree of protection (IP)
IP30
Type of control element
Push button
1SDA055787R1 | E1N 1600 PR122/P-LI IN=1600A 4P W MP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated voltage
690 .. 690V
Adjustment range short-term delayed short-circuit release
960.0 .. 960.0A
Overload release current setting
640.0 .. 1600A
Integrated earth fault protection
Rated permanent current Iu
1600A
Adjustment range undelayed short-circuit release
2400.0 .. 24000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Device construction
Built-in device slide-in technique (withdrawable)
Type of electrical connection of main circuit
Connection at separate chassis part
DIN rail (top hat rail) mounting optional
Suitable for DIN rail (top hat rail) mounting
Number of auxiliary contacts as change-over contact
4
Number of auxiliary contacts as normally closed contact
0
With switched-off indicator
Number of auxiliary contacts as normally open contact
0
Position of connection for main current circuit
Connection at separate chassis part
Number of poles
4
Complete device with protection unit
Motor drive integrated
Motor drive optional
Degree of protection (IP)
IP30
Type of control element
Push button
We use cookies to enhance your experience.