Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Suitable for DIN rail (top hat rail) mountingNo
Overload release current setting800.0 - 2000A
Adjustment range short-term delayed short-circuit release2000 - 20000A
Device constructionBuilt-in device fixed built-in technique
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz42kA
Number of auxiliary contacts as normally open contact0
Integrated earth fault protectionNo
Number of auxiliary contacts as change-over contact4
Rated permanent current Iu2000A
Degree of protection (IP)IP30
Position of connection for main current circuitBack side
DIN rail (top hat rail) mounting optionalNo
Complete device with protection unitYes
Adjustment range undelayed short-circuit release3000.0 - 30000A
Rated voltage690 - 690V
Type of control elementPush button
Number of auxiliary contacts as normally closed contact0
Number of poles4
Type of electrical connection of main circuitBolt connection
Motor drive optionalYes
Motor drive integratedNo
With switched-off indicatorYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA055833R1 | E2B 2000 PR121/P-LSI IN=2000A 4P F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Suitable for DIN rail (top hat rail) mounting

Overload release current setting

800.0 .. 2000A

Adjustment range short-term delayed short-circuit release

2000 .. 20000A

Device construction

Built-in device fixed built-in technique

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

42kA

Number of auxiliary contacts as normally open contact

0

Integrated earth fault protection

Number of auxiliary contacts as change-over contact

4

Rated permanent current Iu

2000A

Degree of protection (IP)

IP30

Position of connection for main current circuit

Back side

DIN rail (top hat rail) mounting optional

Complete device with protection unit

Adjustment range undelayed short-circuit release

3000.0 .. 30000A

Rated voltage

690 .. 690V

Type of control element

Push button

Number of auxiliary contacts as normally closed contact

0

Number of poles

4

Type of electrical connection of main circuit

Bolt connection

Motor drive optional

Motor drive integrated

With switched-off indicator

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.