Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of poles3
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Rated permanent current Iu2000A
Rated voltage690 - 690V
Position of connection for main current circuitBack side
Integrated earth fault protectionNo
Overload release current setting800.0 - 2000A
Motor drive optionalYes
Type of electrical connection of main circuitBolt connection
Type of control elementPush button
Adjustment range undelayed short-circuit release3000.0 - 30000A
Device constructionBuilt-in device fixed built-in technique
With switched-off indicatorYes
Adjustment range short-term delayed short-circuit release1200.0 - 1200.0A
Complete device with protection unitYes
Degree of protection (IP)IP30
Motor drive integratedNo
DIN rail (top hat rail) mounting optionalNo
Number of auxiliary contacts as change-over contact4
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz65kA
Suitable for DIN rail (top hat rail) mountingNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA055923R1 | E2N 2000 PR122/P-LI IN=2000A 3P F HR

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of poles

3

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Rated permanent current Iu

2000A

Rated voltage

690 .. 690V

Position of connection for main current circuit

Back side

Integrated earth fault protection

Overload release current setting

800.0 .. 2000A

Motor drive optional

Type of electrical connection of main circuit

Bolt connection

Type of control element

Push button

Adjustment range undelayed short-circuit release

3000.0 .. 30000A

Device construction

Built-in device fixed built-in technique

With switched-off indicator

Adjustment range short-term delayed short-circuit release

1200.0 .. 1200.0A

Complete device with protection unit

Degree of protection (IP)

IP30

Motor drive integrated

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as change-over contact

4

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

65kA

Suitable for DIN rail (top hat rail) mounting

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.