Aleta.hr
Main Product Image

1SDA055956R1 | E2S 1250 PR122/P-LSI IN=1250A 3P F HR

Code: 1592543

ManufacturerABB
Catalog number1SDA055956R1
EAN code8015644572969

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Type of electrical connection of main circuitBolt connection
Rated voltage690 - 690V
Adjustment range short-term delayed short-circuit release750.0 - 750.0A
Number of auxiliary contacts as normally closed contact0
DIN rail (top hat rail) mounting optionalNo
Suitable for DIN rail (top hat rail) mountingNo
Rated permanent current Iu1250A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz85kA
Device constructionBuilt-in device fixed built-in technique
Type of control elementPush button
Adjustment range undelayed short-circuit release1875.0 - 18750A
Overload release current setting500.0 - 1250A
Number of poles3
With switched-off indicatorYes
Number of auxiliary contacts as normally open contact0
Degree of protection (IP)IP30
Position of connection for main current circuitBack side
Complete device with protection unitYes
Motor drive optionalYes
Integrated earth fault protectionNo
Number of auxiliary contacts as change-over contact4
Motor drive integratedNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA055956R1 | E2S 1250 PR122/P-LSI IN=1250A 3P F HR

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Type of electrical connection of main circuit

Bolt connection

Rated voltage

690 .. 690V

Adjustment range short-term delayed short-circuit release

750.0 .. 750.0A

Number of auxiliary contacts as normally closed contact

0

DIN rail (top hat rail) mounting optional

Suitable for DIN rail (top hat rail) mounting

Rated permanent current Iu

1250A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

85kA

Device construction

Built-in device fixed built-in technique

Type of control element

Push button

Adjustment range undelayed short-circuit release

1875.0 .. 18750A

Overload release current setting

500.0 .. 1250A

Number of poles

3

With switched-off indicator

Number of auxiliary contacts as normally open contact

0

Degree of protection (IP)

IP30

Position of connection for main current circuit

Back side

Complete device with protection unit

Motor drive optional

Integrated earth fault protection

Number of auxiliary contacts as change-over contact

4

Motor drive integrated