Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Integrated earth fault protectionYes
Number of auxiliary contacts as normally closed contact0
Rated voltage690 - 690V
Adjustment range short-term delayed short-circuit release750.0 - 750.0A
Rated permanent current Iu1250A
Type of electrical connection of main circuitBolt connection
Type of control elementPush button
Number of auxiliary contacts as normally open contact0
Device constructionBuilt-in device fixed built-in technique
Number of poles4
Overload release current setting500.0 - 1250A
Adjustment range undelayed short-circuit release1875.0 - 18750A
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as change-over contact4
Position of connection for main current circuitBack side
Motor drive optionalYes
Complete device with protection unitYes
Degree of protection (IP)IP30
Motor drive integratedNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz85kA
DIN rail (top hat rail) mounting optionalNo
With switched-off indicatorYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA055967R1 | E2S 1250 PR123/P-LSIG IN=1250A 4P F HR

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Integrated earth fault protection

Number of auxiliary contacts as normally closed contact

0

Rated voltage

690 .. 690V

Adjustment range short-term delayed short-circuit release

750.0 .. 750.0A

Rated permanent current Iu

1250A

Type of electrical connection of main circuit

Bolt connection

Type of control element

Push button

Number of auxiliary contacts as normally open contact

0

Device construction

Built-in device fixed built-in technique

Number of poles

4

Overload release current setting

500.0 .. 1250A

Adjustment range undelayed short-circuit release

1875.0 .. 18750A

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as change-over contact

4

Position of connection for main current circuit

Back side

Motor drive optional

Complete device with protection unit

Degree of protection (IP)

IP30

Motor drive integrated

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

85kA

DIN rail (top hat rail) mounting optional

With switched-off indicator

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.