Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range undelayed short-circuit release
1875.0 - 18750A
Integrated earth fault protection
No
Suitable for DIN rail (top hat rail) mounting
No
DIN rail (top hat rail) mounting optional
No
Overload release current setting
500.0 - 1250A
Rated permanent current Iu
1250A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Adjustment range short-term delayed short-circuit release
750.0 - 750.0A
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
4
Device construction
Built-in device slide-in technique (withdrawable)
With switched-off indicator
Yes
Type of electrical connection of main circuit
Connection at separate chassis part
Rated voltage
690 - 690V
Number of auxiliary contacts as normally closed contact
0
Number of poles
3
Complete device with protection unit
Yes
Type of control element
Push button
Motor drive integrated
No
Position of connection for main current circuit
Connection at separate chassis part
Degree of protection (IP)
IP30
Motor drive optional
Yes
From same serie
1SDA055972R1 | E2S 1250 PR122/P-LSI IN=1250A 3P W MP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range undelayed short-circuit release
1875.0 .. 18750A
Integrated earth fault protection
Suitable for DIN rail (top hat rail) mounting
DIN rail (top hat rail) mounting optional
Overload release current setting
500.0 .. 1250A
Rated permanent current Iu
1250A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Adjustment range short-term delayed short-circuit release
750.0 .. 750.0A
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
4
Device construction
Built-in device slide-in technique (withdrawable)
With switched-off indicator
Type of electrical connection of main circuit
Connection at separate chassis part
Rated voltage
690 .. 690V
Number of auxiliary contacts as normally closed contact
0
Number of poles
3
Complete device with protection unit
Type of control element
Push button
Motor drive integrated
Position of connection for main current circuit
Connection at separate chassis part
Degree of protection (IP)
IP30
Motor drive optional