  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Motor drive integratedNo
With switched-off indicatorYes
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as change-over contact4
Type of control elementPush button
Type of electrical connection of main circuitBolt connection
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz85kA
Adjustment range short-term delayed short-circuit release1600 - 16000A
Number of auxiliary contacts as normally open contact0
Position of connection for main current circuitBack side
Adjustment range undelayed short-circuit release2400.0 - 24000A
Overload release current setting640.0 - 1600A
Number of auxiliary contacts as normally closed contact0
Degree of protection (IP)IP30
Rated voltage690 - 690V
Rated permanent current Iu1600A
Number of poles3
DIN rail (top hat rail) mounting optionalNo
Motor drive optionalYes
Integrated earth fault protectionYes
Device constructionBuilt-in device fixed built-in technique
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA055986R1 | E2S 1600 PR121/P-LSIG IN=1600A 3P F HR

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Motor drive integrated

With switched-off indicator

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as change-over contact

4

Type of control element

Push button

Type of electrical connection of main circuit

Bolt connection

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

85kA

Adjustment range short-term delayed short-circuit release

1600 .. 16000A

Number of auxiliary contacts as normally open contact

0

Position of connection for main current circuit

Back side

Adjustment range undelayed short-circuit release

2400.0 .. 24000A

Overload release current setting

640.0 .. 1600A

Number of auxiliary contacts as normally closed contact

0

Degree of protection (IP)

IP30

Rated voltage

690 .. 690V

Rated permanent current Iu

1600A

Number of poles

3

DIN rail (top hat rail) mounting optional

Motor drive optional

Integrated earth fault protection

Device construction

Built-in device fixed built-in technique

Complete device with protection unit