Aleta.hr
Main Product Image

1SDA056002R1 | E2S 1600 PR121/P-LSIG IN=1600A 3P W MP

Code: 1592589

ManufacturerABB
Catalog number1SDA056002R1
EAN code8015644573423

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated voltage690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz85kA
Adjustment range short-term delayed short-circuit release1600 - 16000A
Adjustment range undelayed short-circuit release2400.0 - 24000A
Overload release current setting640.0 - 1600A
Rated permanent current Iu1600A
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Device constructionBuilt-in device slide-in technique (withdrawable)
Type of electrical connection of main circuitConnection at separate chassis part
Number of auxiliary contacts as change-over contact4
With switched-off indicatorYes
DIN rail (top hat rail) mounting optionalNo
Complete device with protection unitYes
Position of connection for main current circuitConnection at separate chassis part
Motor drive optionalYes
Suitable for DIN rail (top hat rail) mountingNo
Degree of protection (IP)IP30
Type of control elementPush button
Number of poles3
Integrated earth fault protectionYes
Motor drive integratedNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA056002R1 | E2S 1600 PR121/P-LSIG IN=1600A 3P W MP

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

690 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

85kA

Adjustment range short-term delayed short-circuit release

1600 .. 16000A

Adjustment range undelayed short-circuit release

2400.0 .. 24000A

Overload release current setting

640.0 .. 1600A

Rated permanent current Iu

1600A

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Device construction

Built-in device slide-in technique (withdrawable)

Type of electrical connection of main circuit

Connection at separate chassis part

Number of auxiliary contacts as change-over contact

4

With switched-off indicator

DIN rail (top hat rail) mounting optional

Complete device with protection unit

Position of connection for main current circuit

Connection at separate chassis part

Motor drive optional

Suitable for DIN rail (top hat rail) mounting

Degree of protection (IP)

IP30

Type of control element

Push button

Number of poles

3

Integrated earth fault protection

Motor drive integrated

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.