

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated permanent current Iu
1600A
Rated voltage
690 - 690V
Adjustment range short-term delayed short-circuit release
960.0 - 960.0A
Adjustment range undelayed short-circuit release
2400.0 - 24000A
Device construction
Built-in device slide-in technique (withdrawable)
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Suitable for DIN rail (top hat rail) mounting
No
Overload release current setting
640.0 - 1600A
Type of electrical connection of main circuit
Connection at separate chassis part
Integrated earth fault protection
Yes
DIN rail (top hat rail) mounting optional
No
Number of auxiliary contacts as normally closed contact
0
With switched-off indicator
Yes
Type of control element
Push button
Position of connection for main current circuit
Connection at separate chassis part
Number of auxiliary contacts as normally open contact
0
Degree of protection (IP)
IP30
Motor drive optional
Yes
Complete device with protection unit
Yes
Motor drive integrated
No
Number of poles
4
Number of auxiliary contacts as change-over contact
4
From same serie
1SDA056015R1 | E2S 1600 PR123/P-LSIG IN=1600A 4P W MP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated permanent current Iu
1600A
Rated voltage
690 .. 690V
Adjustment range short-term delayed short-circuit release
960.0 .. 960.0A
Adjustment range undelayed short-circuit release
2400.0 .. 24000A
Device construction
Built-in device slide-in technique (withdrawable)
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Suitable for DIN rail (top hat rail) mounting
Overload release current setting
640.0 .. 1600A
Type of electrical connection of main circuit
Connection at separate chassis part
Integrated earth fault protection
DIN rail (top hat rail) mounting optional
Number of auxiliary contacts as normally closed contact
0
With switched-off indicator
Type of control element
Push button
Position of connection for main current circuit
Connection at separate chassis part
Number of auxiliary contacts as normally open contact
0
Degree of protection (IP)
IP30
Motor drive optional
Complete device with protection unit
Motor drive integrated
Number of poles
4
Number of auxiliary contacts as change-over contact
4
From same serie
We use cookies to enhance your experience.