  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Number of poles3
Rated permanent current Iu1250A
DIN rail (top hat rail) mounting optionalNo
With switched-off indicatorYes
Complete device with protection unitYes
Device constructionBuilt-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mountingNo
Integrated earth fault protectionYes
Motor drive optionalYes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz130kA
Type of electrical connection of main circuitBolt connection
Position of connection for main current circuitBack side
Degree of protection (IP)IP30
Adjustment range short-term delayed short-circuit release750.0 - 750.0A
Type of control elementPush button
Overload release current setting500.0 - 1250A
Motor drive integratedNo
Adjustment range undelayed short-circuit release1875.0 - 18750A
Number of auxiliary contacts as change-over contact4
Rated voltage690 - 690V
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA056055R1 | E2L 1250 PR123/P-LSIG IN=1250A 3P F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Number of poles

3

Rated permanent current Iu

1250A

DIN rail (top hat rail) mounting optional

With switched-off indicator

Complete device with protection unit

Device construction

Built-in device fixed built-in technique

Suitable for DIN rail (top hat rail) mounting

Integrated earth fault protection

Motor drive optional

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

130kA

Type of electrical connection of main circuit

Bolt connection

Position of connection for main current circuit

Back side

Degree of protection (IP)

IP30

Adjustment range short-term delayed short-circuit release

750.0 .. 750.0A

Type of control element

Push button

Overload release current setting

500.0 .. 1250A

Motor drive integrated

Adjustment range undelayed short-circuit release

1875.0 .. 18750A

Number of auxiliary contacts as change-over contact

4

Rated voltage

690 .. 690V

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.