Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated voltage690 - 690V
Overload release current setting640.0 - 1600A
DIN rail (top hat rail) mounting optionalNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz130kA
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range short-term delayed short-circuit release1600 - 16000A
Number of auxiliary contacts as normally closed contact0
Device constructionBuilt-in device fixed built-in technique
Number of auxiliary contacts as normally open contact0
Integrated earth fault protectionYes
Number of auxiliary contacts as change-over contact4
Type of control elementPush button
With switched-off indicatorYes
Number of poles3
Rated permanent current Iu1600A
Position of connection for main current circuitBack side
Motor drive integratedNo
Motor drive optionalYes
Complete device with protection unitYes
Degree of protection (IP)IP30
Type of electrical connection of main circuitBolt connection
Adjustment range undelayed short-circuit release2400.0 - 24000A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA056082R1 | E2L 1600 PR121/P-LSIG IN=1600A 3P F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

690 .. 690V

Overload release current setting

640.0 .. 1600A

DIN rail (top hat rail) mounting optional

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

130kA

Suitable for DIN rail (top hat rail) mounting

Adjustment range short-term delayed short-circuit release

1600 .. 16000A

Number of auxiliary contacts as normally closed contact

0

Device construction

Built-in device fixed built-in technique

Number of auxiliary contacts as normally open contact

0

Integrated earth fault protection

Number of auxiliary contacts as change-over contact

4

Type of control element

Push button

With switched-off indicator

Number of poles

3

Rated permanent current Iu

1600A

Position of connection for main current circuit

Back side

Motor drive integrated

Motor drive optional

Complete device with protection unit

Degree of protection (IP)

IP30

Type of electrical connection of main circuit

Bolt connection

Adjustment range undelayed short-circuit release

2400.0 .. 24000A

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.