Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact4
Adjustment range short-term delayed short-circuit release2500 - 25000A
Number of poles3
Adjustment range undelayed short-circuit release3750.0 - 37500A
Rated permanent current Iu2500A
Overload release current setting1000.0 - 2500A
Motor drive integratedNo
Type of electrical connection of main circuitBolt connection
Degree of protection (IP)IP30
Type of control elementPush button
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz75kA
Position of connection for main current circuitBack side
Number of auxiliary contacts as normally closed contact0
With switched-off indicatorYes
Complete device with protection unitYes
Motor drive optionalYes
Device constructionBuilt-in device fixed built-in technique
DIN rail (top hat rail) mounting optionalNo
Integrated earth fault protectionYes
Rated voltage690 - 690V
Suitable for DIN rail (top hat rail) mountingNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA056274R1 | E3S 2500 PR121/P-LSIG IN=2500A 3P F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

4

Adjustment range short-term delayed short-circuit release

2500 .. 25000A

Number of poles

3

Adjustment range undelayed short-circuit release

3750.0 .. 37500A

Rated permanent current Iu

2500A

Overload release current setting

1000.0 .. 2500A

Motor drive integrated

Type of electrical connection of main circuit

Bolt connection

Degree of protection (IP)

IP30

Type of control element

Push button

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

75kA

Position of connection for main current circuit

Back side

Number of auxiliary contacts as normally closed contact

0

With switched-off indicator

Complete device with protection unit

Motor drive optional

Device construction

Built-in device fixed built-in technique

DIN rail (top hat rail) mounting optional

Integrated earth fault protection

Rated voltage

690 .. 690V

Suitable for DIN rail (top hat rail) mounting

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.