Catalog number1SDA056343R1
EAN code8015644576837

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz100kA
Rated permanent current Iu800A
Rated voltage690 - 690V
Overload release current setting320.0 - 800A
Adjustment range undelayed short-circuit release1200.0 - 12000A
DIN rail (top hat rail) mounting optionalNo
Number of poles3
Type of electrical connection of main circuitBolt connection
Adjustment range short-term delayed short-circuit release480.0 - 480.0A
Position of connection for main current circuitBack side
With switched-off indicatorYes
With under voltage releaseNo
Number of auxiliary contacts as change-over contact4
Suitable for DIN rail (top hat rail) mountingNo
Integrated earth fault protectionYes
Complete device with protection unitYes
Type of control elementPush button
Degree of protection (IP)IP30
Device constructionBuilt-in device fixed built-in technique
Motor drive optionalYes
Motor drive integratedNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA056343R1 | E3H 800 PR123/P-LSIG IN=800A 3P F H

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

100kA

Rated permanent current Iu

800A

Rated voltage

690 .. 690V

Overload release current setting

320.0 .. 800A

Adjustment range undelayed short-circuit release

1200.0 .. 12000A

DIN rail (top hat rail) mounting optional

Number of poles

3

Type of electrical connection of main circuit

Bolt connection

Adjustment range short-term delayed short-circuit release

480.0 .. 480.0A

Position of connection for main current circuit

Back side

With switched-off indicator

With under voltage release

Number of auxiliary contacts as change-over contact

4

Suitable for DIN rail (top hat rail) mounting

Integrated earth fault protection

Complete device with protection unit

Type of control element

Push button

Degree of protection (IP)

IP30

Device construction

Built-in device fixed built-in technique

Motor drive optional

Motor drive integrated