Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact0
Rated permanent current Iu800A
Overload release current setting320.0 - 800A
Number of poles4
Number of auxiliary contacts as change-over contact4
Rated voltage690 - 690V
Degree of protection (IP)IP30
Number of auxiliary contacts as normally closed contact0
Type of control elementPush button
Motor drive optionalYes
Motor drive integratedNo
Position of connection for main current circuitBack side
Integrated earth fault protectionYes
Suitable for DIN rail (top hat rail) mountingNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz100kA
Adjustment range short-term delayed short-circuit release480.0 - 480.0A
Adjustment range undelayed short-circuit release1200.0 - 12000A
With switched-off indicatorYes
Type of electrical connection of main circuitBolt connection
Device constructionBuilt-in device fixed built-in technique
DIN rail (top hat rail) mounting optionalNo
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA056351R1 | E3H 800 PR123/P-LSIG IN=800A 4P F H

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact

0

Rated permanent current Iu

800A

Overload release current setting

320.0 .. 800A

Number of poles

4

Number of auxiliary contacts as change-over contact

4

Rated voltage

690 .. 690V

Degree of protection (IP)

IP30

Number of auxiliary contacts as normally closed contact

0

Type of control element

Push button

Motor drive optional

Motor drive integrated

Position of connection for main current circuit

Back side

Integrated earth fault protection

Suitable for DIN rail (top hat rail) mounting

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

100kA

Adjustment range short-term delayed short-circuit release

480.0 .. 480.0A

Adjustment range undelayed short-circuit release

1200.0 .. 12000A

With switched-off indicator

Type of electrical connection of main circuit

Bolt connection

Device construction

Built-in device fixed built-in technique

DIN rail (top hat rail) mounting optional

Complete device with protection unit

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.