Technical specifications

Number of auxiliary contacts as normally open contact0
Number of poles3
Motor drive integratedNo
Type of control elementPush button
Degree of protection (IP)IP30
Position of connection for main current circuitBack side
Adjustment range undelayed short-circuit release2400.0 - 24000A
With switched-off indicatorYes
Rated voltage690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz100kA
Number of auxiliary contacts as normally closed contact0
Overload release current setting640.0 - 1600A
Number of auxiliary contacts as change-over contact4
Type of electrical connection of main circuitBolt connection
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range short-term delayed short-circuit release960.0 - 960.0A
Rated permanent current Iu1600A
Motor drive optionalYes
Device constructionBuilt-in device fixed built-in technique
Integrated earth fault protectionYes
Complete device with protection unitYes
DIN rail (top hat rail) mounting optionalNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA056405R1 | E3H 1600 PR122/P-LSIG IN=1600A 3P F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact

0

Number of poles

3

Motor drive integrated

Type of control element

Push button

Degree of protection (IP)

IP30

Position of connection for main current circuit

Back side

Adjustment range undelayed short-circuit release

2400.0 .. 24000A

With switched-off indicator

Rated voltage

690 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

100kA

Number of auxiliary contacts as normally closed contact

0

Overload release current setting

640.0 .. 1600A

Number of auxiliary contacts as change-over contact

4

Type of electrical connection of main circuit

Bolt connection

Suitable for DIN rail (top hat rail) mounting

Adjustment range short-term delayed short-circuit release

960.0 .. 960.0A

Rated permanent current Iu

1600A

Motor drive optional

Device construction

Built-in device fixed built-in technique

Integrated earth fault protection

Complete device with protection unit

DIN rail (top hat rail) mounting optional

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.