Aleta.hr
Main Product Image

1SDA056417R1 | E3H 1600 PR121/P-LSI IN=1600A 3P W

Code: 1593004

ManufacturerRAZNO
Catalog number1SDA056417R1
Type
EAN code8015644577575

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

690 - 690V

Adjustment range undelayed short-circuit release

2400.0 - 24000A

Integrated earth fault protection

No

DIN rail (top hat rail) mounting optional

No

With switched-off indicator

Yes

Number of poles

3

Motor drive optional

Yes

Motor drive integrated

No

Rated permanent current Iu

1600A

Position of connection for main current circuit

Connection at separate chassis part

Degree of protection (IP)

IP30

Overload release current setting

640.0 - 1600A

Type of control element

Push button

Type of electrical connection of main circuit

Connection at separate chassis part

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

100kA

Device construction

Built-in device slide-in technique (withdrawable)

Adjustment range short-term delayed short-circuit release

1600 - 16000A

Suitable for DIN rail (top hat rail) mounting

No

With under voltage release

No

Number of auxiliary contacts as change-over contact

4

Complete device with protection unit

Yes

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

1SDA056417R1 | E3H 1600 PR121/P-LSI IN=1600A 3P W

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

690 .. 690V

Adjustment range undelayed short-circuit release

2400.0 .. 24000A

Integrated earth fault protection

DIN rail (top hat rail) mounting optional

With switched-off indicator

Number of poles

3

Motor drive optional

Motor drive integrated

Rated permanent current Iu

1600A

Position of connection for main current circuit

Connection at separate chassis part

Degree of protection (IP)

IP30

Overload release current setting

640.0 .. 1600A

Type of control element

Push button

Type of electrical connection of main circuit

Connection at separate chassis part

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

100kA

Device construction

Built-in device slide-in technique (withdrawable)

Adjustment range short-term delayed short-circuit release

1600 .. 16000A

Suitable for DIN rail (top hat rail) mounting

With under voltage release

Number of auxiliary contacts as change-over contact

4

Complete device with protection unit

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.