Rated permanent current Iu2000A
Rated voltage690 - 690V
Overload release current setting800.0 - 2000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz100kA
Adjustment range undelayed short-circuit release3000.0 - 30000A
Adjustment range short-term delayed short-circuit release2000 - 20000A
Integrated earth fault protectionNo
Type of electrical connection of main circuitBolt connection
Device constructionBuilt-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mountingNo
DIN rail (top hat rail) mounting optionalNo
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as change-over contact4
With switched-off indicatorYes
Type of control elementPush button
Position of connection for main current circuitBack side
Number of poles4
Motor drive optionalYes
Motor drive integratedNo
Degree of protection (IP)IP30
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA056441R1 | E3H 2000 PR121/P-LSI IN=2000A 4P F

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated permanent current Iu

2000A

Rated voltage

690 .. 690V

Overload release current setting

800.0 .. 2000A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

100kA

Adjustment range undelayed short-circuit release

3000.0 .. 30000A

Adjustment range short-term delayed short-circuit release

2000 .. 20000A

Integrated earth fault protection

Type of electrical connection of main circuit

Bolt connection

Device construction

Built-in device fixed built-in technique

Suitable for DIN rail (top hat rail) mounting

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as change-over contact

4

With switched-off indicator

Type of control element

Push button

Position of connection for main current circuit

Back side

Number of poles

4

Motor drive optional

Motor drive integrated

Degree of protection (IP)

IP30