Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Overload release current setting320.0 - 800A
Rated voltage690 - 690V
Adjustment range short-term delayed short-circuit release800 - 8000A
Integrated earth fault protectionNo
Rated permanent current Iu800A
Number of auxiliary contacts as change-over contact4
Number of auxiliary contacts as normally open contact0
Type of electrical connection of main circuitBolt connection
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as normally closed contact0
DIN rail (top hat rail) mounting optionalNo
With switched-off indicatorYes
Position of connection for main current circuitBack side
Number of poles3
Complete device with protection unitYes
Motor drive integratedNo
Device constructionBuilt-in device fixed built-in technique
Motor drive optionalYes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz130kA
Adjustment range undelayed short-circuit release1200.0 - 12000A
Type of control elementPush button
Degree of protection (IP)IP30
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA056529R1 | E3V 800 PR121/P-LSI IN=800A 3P F HR

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Overload release current setting

320.0 .. 800A

Rated voltage

690 .. 690V

Adjustment range short-term delayed short-circuit release

800 .. 8000A

Integrated earth fault protection

Rated permanent current Iu

800A

Number of auxiliary contacts as change-over contact

4

Number of auxiliary contacts as normally open contact

0

Type of electrical connection of main circuit

Bolt connection

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as normally closed contact

0

DIN rail (top hat rail) mounting optional

With switched-off indicator

Position of connection for main current circuit

Back side

Number of poles

3

Complete device with protection unit

Motor drive integrated

Device construction

Built-in device fixed built-in technique

Motor drive optional

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

130kA

Adjustment range undelayed short-circuit release

1200.0 .. 12000A

Type of control element

Push button

Degree of protection (IP)

IP30

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.