Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated voltage
690 - 690V
Rated permanent current Iu
800A
Overload release current setting
320.0 - 800A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
130kA
Adjustment range undelayed short-circuit release
1200.0 - 12000A
Type of electrical connection of main circuit
Connection at separate chassis part
Integrated earth fault protection
No
Adjustment range short-term delayed short-circuit release
800 - 8000A
DIN rail (top hat rail) mounting optional
No
Suitable for DIN rail (top hat rail) mounting
No
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as change-over contact
4
Number of auxiliary contacts as normally open contact
0
Type of control element
Push button
Number of auxiliary contacts as normally closed contact
0
With switched-off indicator
Yes
Position of connection for main current circuit
Connection at separate chassis part
Motor drive optional
Yes
Motor drive integrated
No
Complete device with protection unit
Yes
Degree of protection (IP)
IP30
Number of poles
3
From same serie
1SDA056545R1 | E3V 800 PR121/P-LSI IN=800A 3P W MP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated voltage
690 .. 690V
Rated permanent current Iu
800A
Overload release current setting
320.0 .. 800A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
130kA
Adjustment range undelayed short-circuit release
1200.0 .. 12000A
Type of electrical connection of main circuit
Connection at separate chassis part
Integrated earth fault protection
Adjustment range short-term delayed short-circuit release
800 .. 8000A
DIN rail (top hat rail) mounting optional
Suitable for DIN rail (top hat rail) mounting
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as change-over contact
4
Number of auxiliary contacts as normally open contact
0
Type of control element
Push button
Number of auxiliary contacts as normally closed contact
0
With switched-off indicator
Position of connection for main current circuit
Connection at separate chassis part
Motor drive optional
Motor drive integrated
Complete device with protection unit
Degree of protection (IP)
IP30
Number of poles
3
From same serie