Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Overload release current setting
320.0 - 800A
Number of auxiliary contacts as normally open contact
0
Motor drive optional
Yes
With switched-off indicator
Yes
Number of poles
3
Device construction
Built-in device slide-in technique (withdrawable)
Type of electrical connection of main circuit
Connection at separate chassis part
Rated voltage
690 - 690V
Rated permanent current Iu
800A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
130kA
Suitable for DIN rail (top hat rail) mounting
No
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
4
Adjustment range short-term delayed short-circuit release
480.0 - 480.0A
DIN rail (top hat rail) mounting optional
No
Adjustment range undelayed short-circuit release
1200.0 - 12000A
Degree of protection (IP)
IP30
Position of connection for main current circuit
Connection at separate chassis part
Type of control element
Push button
Motor drive integrated
No
Integrated earth fault protection
No
Complete device with protection unit
Yes
From same serie
1SDA056548R1 | E3V 800 PR122/P-LSI IN=800A 3P W MP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Overload release current setting
320.0 .. 800A
Number of auxiliary contacts as normally open contact
0
Motor drive optional
With switched-off indicator
Number of poles
3
Device construction
Built-in device slide-in technique (withdrawable)
Type of electrical connection of main circuit
Connection at separate chassis part
Rated voltage
690 .. 690V
Rated permanent current Iu
800A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
130kA
Suitable for DIN rail (top hat rail) mounting
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
4
Adjustment range short-term delayed short-circuit release
480.0 .. 480.0A
DIN rail (top hat rail) mounting optional
Adjustment range undelayed short-circuit release
1200.0 .. 12000A
Degree of protection (IP)
IP30
Position of connection for main current circuit
Connection at separate chassis part
Type of control element
Push button
Motor drive integrated
Integrated earth fault protection
Complete device with protection unit
From same serie
We use cookies to enhance your experience.