Aleta.hr
Main Product Image

1SDA056575R1 | E3V 1250 PR123/P-LSIG IN=1250A 4P F HR

Code: 1593162

ManufacturerABB
Catalog number1SDA056575R1
EAN code8015644579159

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Adjustment range short-term delayed short-circuit release750.0 - 750.0A
Rated permanent current Iu1250A
Position of connection for main current circuitBack side
With switched-off indicatorYes
Complete device with protection unitYes
Rated voltage690 - 690V
Type of control elementPush button
Type of electrical connection of main circuitBolt connection
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz130kA
Adjustment range undelayed short-circuit release1875.0 - 18750A
Number of auxiliary contacts as change-over contact4
Integrated earth fault protectionYes
Device constructionBuilt-in device fixed built-in technique
DIN rail (top hat rail) mounting optionalNo
Suitable for DIN rail (top hat rail) mountingNo
Overload release current setting500.0 - 1250A
Motor drive optionalYes
Number of poles4
Motor drive integratedNo
With under voltage releaseNo
Degree of protection (IP)IP30
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA056575R1 | E3V 1250 PR123/P-LSIG IN=1250A 4P F HR

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Adjustment range short-term delayed short-circuit release

750.0 .. 750.0A

Rated permanent current Iu

1250A

Position of connection for main current circuit

Back side

With switched-off indicator

Complete device with protection unit

Rated voltage

690 .. 690V

Type of control element

Push button

Type of electrical connection of main circuit

Bolt connection

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

130kA

Adjustment range undelayed short-circuit release

1875.0 .. 18750A

Number of auxiliary contacts as change-over contact

4

Integrated earth fault protection

Device construction

Built-in device fixed built-in technique

DIN rail (top hat rail) mounting optional

Suitable for DIN rail (top hat rail) mounting

Overload release current setting

500.0 .. 1250A

Motor drive optional

Number of poles

4

Motor drive integrated

With under voltage release

Degree of protection (IP)

IP30