Aleta.hr
Main Product Image

1SDA056585R1 | E3V 1250 PR121/P-LSI IN=1250A 4P W MP

Code: 1593172

ManufacturerABB
Catalog number1SDA056585R1
EAN code8015644579258

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated voltage690 - 690V
Rated permanent current Iu1250A
Integrated earth fault protectionNo
Adjustment range short-term delayed short-circuit release1250 - 12500A
Adjustment range undelayed short-circuit release1875.0 - 18750A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz130kA
Type of electrical connection of main circuitConnection at separate chassis part
With switched-off indicatorYes
DIN rail (top hat rail) mounting optionalNo
Device constructionBuilt-in device slide-in technique (withdrawable)
Position of connection for main current circuitConnection at separate chassis part
With under voltage releaseNo
Complete device with protection unitYes
Number of auxiliary contacts as change-over contact4
Overload release current setting500.0 - 1250A
Motor drive optionalYes
Suitable for DIN rail (top hat rail) mountingNo
Degree of protection (IP)IP30
Number of poles4
Motor drive integratedNo
Type of control elementPush button
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA056585R1 | E3V 1250 PR121/P-LSI IN=1250A 4P W MP

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

690 .. 690V

Rated permanent current Iu

1250A

Integrated earth fault protection

Adjustment range short-term delayed short-circuit release

1250 .. 12500A

Adjustment range undelayed short-circuit release

1875.0 .. 18750A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

130kA

Type of electrical connection of main circuit

Connection at separate chassis part

With switched-off indicator

DIN rail (top hat rail) mounting optional

Device construction

Built-in device slide-in technique (withdrawable)

Position of connection for main current circuit

Connection at separate chassis part

With under voltage release

Complete device with protection unit

Number of auxiliary contacts as change-over contact

4

Overload release current setting

500.0 .. 1250A

Motor drive optional

Suitable for DIN rail (top hat rail) mounting

Degree of protection (IP)

IP30

Number of poles

4

Motor drive integrated

Type of control element

Push button

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.