  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

With switched-off indicatorYes
Number of poles3
Degree of protection (IP)IP30
Overload release current setting800.0 - 2000A
Adjustment range undelayed short-circuit release3000.0 - 30000A
Adjustment range short-term delayed short-circuit release1200.0 - 1200.0A
Number of auxiliary contacts as change-over contact4
Position of connection for main current circuitBack side
Type of electrical connection of main circuitBolt connection
Number of auxiliary contacts as normally closed contact0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz130kA
Rated voltage690 - 690V
Type of control elementPush button
Number of auxiliary contacts as normally open contact0
Rated permanent current Iu2000A
Motor drive integratedNo
Suitable for DIN rail (top hat rail) mountingNo
Integrated earth fault protectionYes
Motor drive optionalYes
Device constructionBuilt-in device fixed built-in technique
Complete device with protection unitYes
DIN rail (top hat rail) mounting optionalNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA056631R1 | E3V 2000 PR123/P-LSIG IN=2000A 3P F HR

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

With switched-off indicator

Number of poles

3

Degree of protection (IP)

IP30

Overload release current setting

800.0 .. 2000A

Adjustment range undelayed short-circuit release

3000.0 .. 30000A

Adjustment range short-term delayed short-circuit release

1200.0 .. 1200.0A

Number of auxiliary contacts as change-over contact

4

Position of connection for main current circuit

Back side

Type of electrical connection of main circuit

Bolt connection

Number of auxiliary contacts as normally closed contact

0

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

130kA

Rated voltage

690 .. 690V

Type of control element

Push button

Number of auxiliary contacts as normally open contact

0

Rated permanent current Iu

2000A

Motor drive integrated

Suitable for DIN rail (top hat rail) mounting

Integrated earth fault protection

Motor drive optional

Device construction

Built-in device fixed built-in technique

Complete device with protection unit

DIN rail (top hat rail) mounting optional

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.